AMETEK Products

 

 

 

SERIES 1100 - FRODE PEDERSEN TEMPERATURE SENSORS
 

Application
Measurement of high temperature in big furnaces and ducts with combustion gasses and air. The operating range is up to 1100°C (shortly 1200°C)


1101- Type AMK

Thermocouple assembly AMK with steel protective tube and ceramic inner tube


Fields of application:
- Furnaces
- Refuse and hazardous waste incineration plants
- Brickworks

Technical features:
- Outer protective tube in heat-resistant steel
- Gas-tight ceramic inner tube for protecting the thermocouple against contamination
- Modular design and standard length minimize the necessary numbers of spares
- Connected to the process by adjustable flange or compression fitting
- Thermocouple type K, N, R, S or B acc. to IEC 584-1
- Optionally, can be supplied with head mounted transmitter

Ordering:
The requested sensor is selected from the below specification sheet

1101 Series - - - Frode Pedersen temperature sensors - - - Specification sheet in English

Application
Measurement of high temperature in big furnaces and ducts with combustion gasses and air. The operating range is up to 1600°C


1102- Type AMK

Thermocouple assembly AMK with ceramic protective tube and ceramic inner tube (double protection)
 

Fields of application:

- Brickworks, porcelain factories
- Refuse and hazardous waste incineration plants
- Chemical process engineering

Technical features:
- Thermocouple type K, N, R, S or B acc. to IEC 584-1
- Connected to the process by adjustable flange or compression fitting
- Gas-tight ceramic inner tube for protecting the thermocouple against contamination
- Gas-tight ceramic outer protective tube
- Modular design and standard length minimize the necessary numbers of spares
- Optionally, can be supplied with head mounted transmitter

Ordering:
The requested sensor is selected from the below specification sheet

1102 Series - - - Frode Pedersen temperature sensors - - - Specification sheet in English

Application
For technical temperature measurements in combustion processes and hot-gas environments, primarily in all types of furnaces up to 1500°C (shortly 1800°C)


1103 - Type AK

Thermocouple assembly AK with ceramic protective tube


Fields of application
- Brickworks, porcelain factories
- Refuse and hazardous waste incineration
- Glass annealing ovens, ceramic baking ovens

Technical features:
- Modular design and standard length minimize the necessary numbers of spares
- Optionally, can be supplied with head mounted transmitter
- Thermocouple type K, N, R, S or B acc. to IEC 584-1
- Built acc. to DIN 43733
- Connected to the process by adjustable flange, gas-tight flange or compression fitting
- Gas-tight ceramic protective tube in KER 610 or KER 710
- Nominal length
- Retaining tube

Ordering:
The requested sensor is selected from the below specification sheet

1103 Series - - - Frode Pedersen temperature sensors - - - Specification sheet in English
 

Application

Measurement of high temperature in furnaces and ducts with combustion gasses and air. The operating range is up to 900°C (shortly 1200°C)



1104 - Type BMK

Thermocouple assembly with steel protective tube and ceramic inner tube

Fields of application

- Power plants
- Energy and furnaces
- Annealing and thermal treatment processes

Technical features:
- Thermocouple type K and N acc. to IEC 584-1
- Connected to the process by adjustable flange or compression fitting
- Gas-tight ceramic inner tube for protecting the thermocouple against contamination
- Outer protective tube in heat-resistant steel
- Modular design and standard length minimize the necessary numbers of spares
- Optionally, can be supplied with head mounted transmitter

Ordering:

The requested sensor is selected from the below specification sheet.


Application

For temperature measurements in combustion processes and hot-gas environment. The operating range is up to 1500°C (shortly 1800°C)



1105 - Type BK

With ceramic protective tube


Fields of application:
- Ceramic industry
- Research and test plants
- Process industry - combustion, furnaces and heat treatment

Technical features:
- Thermocouple type K, N, R, S or B acc. to IEC 584-1
- Connected to the process by adjustable flange or gas-tight compression fitting
- Gas-tight ceramic protective tube in KER 610 or KER 710
- Modular design and standard length minimize the necessary numbers
- Optionally, can be supplied with head mounted transmitter

Ordering:
The requested sensor is selected from the below specification sheet


1105 Series - - - Frode Pedersen temperature sensors - - - Specification sheet in English

Application

For technical temperature measurements in combustion processes and hot-gas environments, primarily in all types of furnaces up to 1200°C (shortly 1300°C)



1106 - Type AKT
With measuring insert and ceramic outer protective tube


Fields of application:

- Refuse and hazardous waste incinerations plants.

The combination of high temperature, corrosive gasses and particles demands special features in relation to life-time for the sensor and minimize process down-time

Technical features:
- Modular design and standard length minimize the necessary numbers of spares
- Thermocouple type N and K acc to IEC584-1
- Interchangeable measuring insert, mineral insulated with high heat and corrosive resistance sheath
- Connected to the process by adjustable flange, gas-tight flange or compression fitting
- Gas-tight ceramic protective tube in KER 610 or KER 710
- Optionally, can be supplied with head mounted transmitter

Ordering:
The requested sensor is selected from the below specification sheet


1106 Series - - - Frode Pedersen temperature sensors - - - Specification sheet in English


See more

Frode Pedersen Temperature Sensors

Ametek Temperature Calibrators

 

 


     Subscribe to our product specials newsletter.

  Terms and Conditions :: Privacy Policy

© 2009 Digital Measurement Metrology, Inc.
Toronto, Ontario, CANADA