SERIES 1100 - FRODE PEDERSEN TEMPERATURE SENSORS
|
|
Application |
|
|
Measurement of high temperature in big furnaces and ducts with combustion gasses and air. The operating range is up to 1100°C (shortly 1200°C) |

1101- Type AMK Thermocouple assembly AMK with steel protective tube and ceramic inner tube
|
|
Fields of application: - Furnaces - Refuse and hazardous waste incineration plants - Brickworks
Technical features: - Outer protective tube in heat-resistant steel - Gas-tight ceramic inner tube for protecting the thermocouple against contamination - Modular design and standard length minimize the necessary numbers of spares - Connected to the process by adjustable flange or compression fitting - Thermocouple type K, N, R, S or B acc. to IEC 584-1 - Optionally, can be supplied with head mounted transmitter
Ordering: The requested sensor is selected from the below specification sheet |
|
|
|
|
|
|
Application |
|
|
Measurement of high temperature in big furnaces and ducts with combustion gasses and air. The operating range is up to 1600°C |

1102- Type AMK Thermocouple assembly AMK with ceramic protective tube and ceramic inner tube (double protection)
|
|
Fields of application: - Brickworks, porcelain factories - Refuse and hazardous waste incineration plants -
Chemical process engineering
Technical features: - Thermocouple type K, N, R, S or B acc. to IEC 584-1 - Connected to the process by adjustable flange or compression fitting - Gas-tight ceramic inner tube for protecting the thermocouple against contamination - Gas-tight ceramic outer protective tube - Modular design and standard length minimize the necessary numbers of spares - Optionally, can be supplied with head mounted transmitter
Ordering: The requested sensor is selected from the below specification sheet |
|
|
|
|
|
|
Application |
|
|
For technical temperature measurements in combustion processes and hot-gas environments, primarily in all types of furnaces up to 1500°C (shortly 1800°C) |

1103 - Type AK Thermocouple assembly AK with ceramic protective tube
|
|
Fields of application - Brickworks, porcelain factories - Refuse and hazardous waste incineration - Glass annealing ovens, ceramic baking ovens
Technical features: - Modular design and standard length minimize the necessary numbers of spares - Optionally, can be supplied with head mounted transmitter - Thermocouple type K, N, R, S or B acc. to IEC 584-1 - Built acc. to DIN 43733 - Connected to the process by adjustable flange, gas-tight flange or compression fitting - Gas-tight ceramic protective tube in KER 610 or KER 710 - Nominal length - Retaining tube
Ordering: The requested sensor is selected from the below specification sheet |
|
|
|
|
|
|
Application |
|
|
Measurement of high temperature in furnaces and ducts with combustion gasses and air. The operating range is up to 900°C (shortly 1200°C) |

1104 - Type BMK Thermocouple assembly with steel protective tube and ceramic inner tube
|
|
Fields of application - Power plants - Energy and furnaces - Annealing and thermal treatment
processes
Technical features: - Thermocouple type K and N acc. to IEC 584-1 - Connected to the process by adjustable flange or compression fitting - Gas-tight ceramic inner tube for protecting the thermocouple against contamination
- Outer protective tube in heat-resistant steel - Modular design and standard length minimize the necessary numbers of spares - Optionally, can be supplied with head mounted transmitter
Ordering: The requested sensor is selected from the below specification sheet. |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
Application |
|
|
For temperature measurements in combustion processes and hot-gas environment. The operating range is up to 1500°C (shortly 1800°C) |

1105 - Type BK With ceramic protective tube
|
|
Fields of application: - Ceramic industry - Research and test plants - Process industry - combustion, furnaces and heat treatment
Technical features: - Thermocouple type K, N, R, S or B acc. to IEC 584-1 - Connected to the process by adjustable flange or gas-tight compression fitting - Gas-tight ceramic protective tube in KER 610 or KER 710 - Modular design and standard length minimize the necessary numbers - Optionally, can be supplied with head mounted transmitter
Ordering: The requested sensor is selected from the below specification sheet |
|
|
|
|
|
|
Application |
|
|
For technical temperature measurements in combustion processes and hot-gas environments, primarily in all types of furnaces up to 1200°C (shortly 1300°C) |

1106 - Type AKT
With measuring insert and ceramic outer protective tube
|
|
Fields of application: - Refuse and hazardous waste incinerations plants.
The combination of high temperature, corrosive gasses and particles demands special features in relation to life-time for the sensor and minimize process down-time
Technical features: - Modular design and standard length minimize the necessary numbers of spares - Thermocouple type N and K acc to IEC584-1 - Interchangeable measuring insert, mineral insulated with high heat and
corrosive resistance sheath - Connected to the process by adjustable flange, gas-tight flange or compression fitting - Gas-tight ceramic protective tube in KER 610 or KER 710 - Optionally, can be supplied with head mounted transmitter
Ordering: The requested sensor is selected from the below specification sheet |
|
|
|
|
|
See more Frode Pedersen Temperature Sensors
Ametek
Temperature Calibrators
|
|
|
|
|