AMETEK Products

 

 

 

JOFRA AMC900 - Advanced Multi-purpose Calibrator
The AMC900 bench calibrator is your solution for high precision signal, temperature, and pressure calibrations. 


This multi-purpose unit offers laboratory grade accuracy at an industrial calibrator price. The standard is delivered pre-loaded with 13 thermocouple curves and 14 RTD curves. You can also program curves to suit your individual needs. With the optional external pressure modules, you can tailor the system to address your
calibration needs.

The JOFRA AMC900 not only offers temperature and pressure calibration features, it includes sourcing of current and voltage and measurement of millivolts, and resistance. This flexibility means that you need only one unit for calibration or verification. This standard gives you the confidence you need for your test instruments as well as in your field calibrations. Upgrade your laboratory or workshop to a higher level of accuracy and flexibility with the AMC900.

The JOFRA AMC900 has the ability to store up to 9 setpoints for each output range. The setpoints can be selected manually or automatically stepped at timed intervals. The AMC900 also features an easy-to-operate front panel user interface and computer control through an RS232 or IEEE-488 interface for automated production testing. The unit sources DC voltage and current for multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multi-meters, handheld calibrators, and other industrial instruments. This is the cost-effective solution for your multiple calibration needs.


Laboratory standard for electrical signals, handheld calibrators, and bench testing of instrumentation.

Output:
DC current 0-100 mA
DC voltage 0 to 100 V
DC mV 0 to 100 mV
TC simulation -10 to 75 mV
Resistance 5 to 4000 ohm
(RTD simulation)

Input:
DC mV -10 to 75 mV
(TC temperature conversion)
Resistance 0 to 4000 ohm
(RTD temperature. conversion)
Pressure modules.

Fully remote controllable with a parallel instrument bus IEEE-488 and RS232 serial interface.

Pressure reference capability increases the fl exibility of the instrument
with the addition of external pressure modules. Accuracies up to 0.01%.

Temperature reference
13 different Thermocouple types,
14 different RTD types
Accuracies of up to 0.025°C.

Fast RTD simulation works with all pulsed transmitters.

See other signal calibrators:
JOFRA ASC300 Series

JOFRA CSC200 Series
JOFRA CSC100 Series
JOFRA mAcal

 

 



PRODUCT INFORMATION (Specification sheets)
You need the 'Acrobat Reader' to read PDF documents. Use this link to download the Adobe Acrobat Reader .

 

JOFRA AMC900 - - - - Signal calibrator - - - - Specification sheet in English

 

 

Request more information about this product



See more

Jofra Process Signal Calibrators


     Subscribe to our product specials newsletter.

  Terms and Conditions :: Privacy Policy

© 2009 Digital Measurement Metrology, Inc.
Toronto, Ontario, CANADA