AMETEK Products

 

 

 

JOFRA CTC SERIES DRY-BLOCK CALIBRATORS
 
Fast and easy-to-use reliable true temperature calibration in the field
     


C ompact
T empearture
C alibrator

The JOFRA CTC series of dry-block calibrators has been designed for much easier true temperature calibration in the field, leading to reliable results. The simple operation and the automatic functions have been carefully selected for ease of use. This has resulted in a fast, simple and efficient temperature calibrator without compromising quality. Reach 320°C / 608°F in just 4 minutes....

  • Interchangeable inserts
     
  • Multi-hole insertion tubes
     
  • MVI Mains Variance Immunity
     
  • Automatic switch test
     
  • RS 232 and JOFRACAL calibration software
     
  • Multi information display
     
  • Safty banana bushings
     
  • Auto stepping
     
  • Stability indicator
     
  • Count down timer (shows when unit is stable)
     
  • Programmable maximum temperature
     
  • Fast simulation/training mode
     
  • Re-calibration from keyboard

Model and temperature range:

CTC-140 A.........-17 to 140°C / -1 to 284°F
CTC-320 A..........33  to 320°C / 91 to 608°F
CTC-320 B..........33  to 320°C / 91 to 608°F
CTC-650 A..........33  to 650°C / 91 to 1202°F
CTC-650 B..........33  to 650°C / 91 to 1202°F
CTC-1200 A......300 to 1200°C / 572 to 2200°F --- NEW ---

 
 

 

See others dry-block calibrators:
JOFRA ATC Series

JOFRA ITC Series
JOFRA MTC Series
JOFRA ETC Series

     
     

 
  Six models - The JOFRA CTC series consists of six different models which differ in temperature range and immersion depth. All units offer similar features and the large, backlit LCD display panel, which is easy-to-read even in well-lit areas. A rugged, slim-line, aluminium outer casing with die-cast top and bottom protects the CTC series of dry-blocks.

Well - optimized for speed - The special designed heating block profile reduces the mass so it heats up and cools down very quickly. The design still offers good stability and accuracy.

High flexibility - You are not limited by fixed holes. Interchangeable insertion tubes are used to match the diameter of your sensor-under-test. Also multihole inserts are available.
     

 
  Switch test - Fully automatic test of thermo switches. The calibrator will find the closing and the opening temperatures and calculate the hysteresis. This makes you save time and leaves you free to concentrate on other things while the test is running.

 
     

 
  Auto step - The calibrator will automatically change to the next programmed value. This allows the calibrator to be placed anywhere in the process while you monitor the output from the sensor-under-test in the control room.
     
    Easy maintenance - If adjustment of the calibrator is needed, use the built-in routine. No need for a computer or a screwdriver. "Calibration Date" is shown each time the instrument is switched on.
 
     

 
  MVI circuitry - The MVI technology removes the stability problem caused by an unstable mains supply. This is very often a problem in production environments with large electric motors, heating elements, etc. cycling on and off.

More about MVI
 
     

 
  Stability indicator - Clear audio and visual indication in the display when the calibrator is stable.
     
  Simplified calibration documentation - All JOFRA CTC series calibrators are delivered with an RS232 serial interface and the JOFRACAL calibration software.
JOFRACAL software presents the means for an entirely automatic calibration of sensors and a semi-automatic calibration of the complete process loop through the use of a PC.

More about JOFRACAL.
 


 

Key specifications:
 
Spec's at 23°C (73°F) ambient
 
CTC140A
 
CTC320A
 
CTC650A
 
CTC320B
 
CTC650B
 
CTC1200A
 
Min. temp. -17°C
/ -1°F
 
33°C
/ 91°F
 
33°C
/ 91°F
 
33°C
/ 122°F
 
33°C
/ 122°F
 
300°C
/ 572°F
 
Max. temp.
 
140°C
/ 284°F
 
320°C
/ 608°F
 
650°C
/ 1202°F
 
320°C
/ 608°F
 
650°C
/ 1202°F
 
1205°C
/ 2200°F
 
Heating time
 
15 min.
 
4 min.
 
10 min.
 
20 min.
 
39 min. 45 min.
 
Accuracy 0.4°C
/ 0.7°F
0.5°C
/ 0.9°F
0.9°C
/ 1.6°F
0.5°C
/ 0.9°F
0.6°C
/ 1.1°F
2.0°C
/ 3.6°F
Stability
 
0.05°C
/ 0.09°F
 
0.1°C
/ 0.18°F
 
0.1°C
/ 0.18°F
 
0.1°C
/ 0.18°F
 
0.05°C
/ 0.09°F
0.1°C
/ 0.18°F
 
Immersion depth
 
115 mm
/ 4.5 in.
 
110 mm
/ 4.3 in.
 
110 mm
/ 4.3 in.
 
190 mm
/ 7.5 in.
 
190 mm
/ 7.5 in.
110 mm
/ 4.3 in.
 
Insert diameter
 
19 mm
/ 3/4 in.
 
26 mm
/ 1 in.
 
26 mm
/ 1 in.
 
26 mm
/ 1 in.
 
26 mm
/ 1 in.
27 mm
/ 1 in.
 
 

 
PRODUCT INFORMATION (Specification sheets)
You need the 'Acrobat Reader' to read PDF documents. Use this link to download the Adobe Acrobat Reader .

 

 

JOFRA CTC Series - - - - Dry-block - - - - Specification sheet in English


 

JOFRA CTC Series - - - - Dry-block - - - - Specification sheet in French


 


 

User Manual JOFRA CTC-140/320/650 A/B and 1200 A

 

Reference Manual JOFRA CTC-140/320/650 A/B and 1200 A
 

Request more information about this product
 

 


See more

JOFRA DRY-BLOCK CALIBRATORS

Ametek Temperature Calibrators



     Subscribe to our product specials newsletter.

  Terms and Conditions :: Privacy Policy

© 2009 Digital Measurement Metrology, Inc.
Toronto, Ontario, CANADA